Low subcool low superheat - Part 1 of this article covered how to calculate total temperature glide, effective temperature glide, fractionation, average evaporator and condenser temperature, evaporator superheat, and condenser subcooling for refrigerant blends that have a temperature glide. This article will offer a quick review of evaporator superheat and condenser subcooling calculations, then create a scenario where a ...

 
Attach the Manifold Gauges. Connect the manifold gauges to the low-pressure port. Ensure it is attached securely to prevent any leakages and to get accurate readings. Take Temperature and Pressure Readings. Using a thermometer, take the temperature reading of the suction line — this is the line that carries the refrigerant back to the unit.. Lawrence indiana fireworks 2023

Just like with subcooling, low or high superheat readings mean that the system either has too little or too much refrigerant in most cases. Low superheat means that there is too much in the evaporator. High superheat means that there is not enough in the evaporator. High superheat can be caused by restrictions in the line, significant airflow ...Does the system really need Freon? In this video, Bryan shows how you can answer that question by covering the signs of low AC refrigerant charge. That way, ...LOW SUPERHEAT LOW SUBCOOLING TXV. Low superheat indicates that there is an excess amount of refrigerant in the evaporator, or the heat load is not sufficient to vaporize the liquid refrigerant to vapor before it moves to the compressor resulting in compressor damage. Plugging of the evaporator coils can also result in low superheat.Originally Posted by Brad gall. .12 degree subcooling and 0 on the superheat both measured at the condenser.. This just don't make sense to me, you would think with only a 12° SC if you were able to get that with a wide open valve, that there would be some flashing, and not have a 0 SH, heck you got me.Low Superheat Normal Subcooling. This is another state where low superheat normal subcooling occurs due to 2 pertinent reasons including plugged evaporator coils and plugged air filters. The main ingredient involved in normal subcooling despite the lower superheat is a liquid line receiver Which is installed in the refrigeration system.The main reasons your compressor will have simultaneously low head pressure and high suction pressure is due to: Bad or leaky compressor valves. Worn compressor piston rings. Leaky oil separator return line. Your compressor valves may become inefficient due to poor sealing from dirt and debris deposits.The following readings were taken on a 87 degree day aproximately 50% humidity with a indoor temperature of 82 degrees. Low pressure 62psi @ 65 degrees superheat=30 degrees, High pressure 330psi @ 90 degrees sub cooling = 40 degees. inside temperature differential aprox 14 degrees.Therefore the Superheat will be high when the charge is low (assumes cap tube). A low charge also lowers the head pressure (and corresponding saturation temperature). The gas takes longer to condense due to extra heat. This leaves less time for subcooling at condenser exit, hence a low subcooling reading. Sound good?Check into superheat when the house is extremely warm will give you an inaccurate reading but your temperature drop should be 15 to 20 degrees. The more humid it is outside in the summer the lower your temperature drops going to be puts more load on the AC. I do a triple evac with nitro to remove non condensables.A high superheat, a warm suction line, and 0 degrees subcooling in an A/C system likely indicate a low refrigerant charge. These symptoms show inefficient heat absorption in the evaporator and inadequate refrigerant to condense in the condenser. Therefore the correct answer is: A) Explanation:The unit is a 3 1/2 Ton heat pump. Original problem was the Evap froze up. Went there and sure enough it was low on charge. TXV equipped. 410A. Data label is calling for a 14 subcool. I put the gauges on and I’m showing a 2. I use a Fieldpiece sman4. I end up putting 15lbs of 410 in and eventually get it to a 12 subcool. Everything is …Subcooling is a temperature below saturated pressure-temperature (Table 1). Subcooling is a measurement of how much liquid is in the condenser. In air conditioning, it is important to measure subcooling because the longer the liquid stays in the condenser, the greater the sensible (visible) heat loss. Low subcooling means that a condenser is empty.High superheat means there's a lot of refrigerant vapor, while low superheat means there's almost none. In a properly operating system, you should have cool vapor leaving the evaporator that moves through the suction line, service valve, and into the compressor. ... It's easy to misdiagnose superheat and subcooling readings when you're ...To understand superheat or subcooling we must first understand Saturation\u000B\u000BSaturation\u000B#1 Pressure (PSIG) converted to a Saturated temperature. \u000BSuction saturated is the Blue, low pressure, suction gauge pressure converted to a vapor/ Dewpoint/ suction saturated temperature.\u000BLiquid Saturated is theOvercharged systems have higher-than-normal amounts of subcooling. Undercharged systems have low subcooling. Comparing high-side subcooling and low-side system superheat will usually solve most refrigeration cycle problems of overcharge, undercharge, and restrictions. Normal evaporator air temperature drop is 18° to 20°.In this video, see how to use the superheat and subcooling troubleshooting procedure to evaluate a refrigeration or air conditioning system. To learn about t...Over Charge- If refrigerant charge is high, the superheat will be low. The low side pressure will be higher than normal. This indicates the refrigerant did not absorb enough heat to properly change to a vapor. Liquid refrigerant may enter the compressor if superheat is too low. Dirty Evaporator Coil- A dirty air filter, evaporator coil or lack ...A lot of times when I am checking TXV equipped units I'll have normal pressures with a very low subcool. For example. 75 indoor. 20 delta t. 85 outdoor. Pressures around 320/130 psi. Subcooling 2. What would cause this? Now I know low subcool could be indicative of a low charge but with these pressures and good delta t I don't think this is the case.Liquid line temp 101 degrees and the suction was 49 degrees. The low subcooling and low suction pressure indicate low airflow. The somewhat low deltaT seems to contradict that. Could be a significant amount of air bypassing the coil based on your report, which would account for all of the numbers that you posted. High pressures can cause refrigerant leaks at the condenser, leading to high superheat and low subcooling. To avoid these issues, ensure sufficient airflow by keeping condenser coils and fins clean. 2. Malfunctioned Metering Devices. The metering tool controls the refrigerant flow. A malfunctioning tool can result in refrigerant flow ... For example, a very low reading (between 0 degrees to 10 degrees subcooling) indicates that the refrigerant did not lose the normal amount of heat in its …When calculating superheat, we use the "dew point." We use the "bubble point when calculating subcooling. The saturation temperature is the range of temperatures between those two points; a temperature could be "interpreted" as negative superheat or subcooling when it is actually just in the saturated range. In air conditioning, the ...Low suction pressure, low superheat and low subcooling are a good indicator of poor airflow. Generally SH should be 10-15 and SC around 12. Now, once we establish airflow, next step is to confirm metering device - is it a piston or TXV? With a piston, we go by superheat. Add refrigerant to lower superheat or remove refrigerant to raise superheat.Superheat is calculated as the difference between the saturation temperature of a substance and the actual temperature of the gas. 3 When it comes to HVAC, refrigerants often boil at much lower temperatures than water. For example, if a liquid refrigerant boils at -10 degrees and is then heated up to -5 degrees, it has been superheated by 5 ...How to Check Subcooling. Attach the thermometer to the liquid line. This time, near the condenser. Then take the head pressure in Psi and convert it to the temperature on the pressure/temperature chart. Assuming you are dealing with a R22 system, let's say the head pressure is 260Psi. This will convert to 120F.Attach the Manifold Gauges. Connect the manifold gauges to the low-pressure port. Ensure it is attached securely to prevent any leakages and to get accurate readings. Take Temperature and Pressure Readings. Using a thermometer, take the temperature reading of the suction line — this is the line that carries the refrigerant back to the unit.May 19, 2023 · 💡. If your portable AC keeps turning off, see our guide to learn about it. Low Superheat Low Subcooling; The Pertinent Reasons. There can be different reasons for low superheat including refrigerant in the oil in excess amount in comparison to a load of heat. 163K subscribers in the HVAC community. A subreddit for Heating, Ventilation, & Air Conditioning Technicians. If you are not a member of the trade… What causes low superheat and high subcooling? Because these readings are normal, the low suction pressure is caused by insufficient heat getting to the evaporator rather than low refrigerant. CAUSE #2: A faulty, plugged-in, or undersized metering device is to blame. As refrigerant is added to TXV systems with high superheat, double-check the ... Low subcooling means that a condenser is almost empty. High subcooling means that a condenser is over field of liquid. 1) The amount of refrigerant entering the metering orifice is the Outdoor Dry bulb. 2) The total heat of the air entering the evaporator coil is the Indoor Wet bulb. With 95 degrees outside air.Replace air filters and the blower wheel. Overfeeding of the metering device. Ensure sensing valve of the TXV is properly insulated. Insufficient heat load to the coil. Clean the filters and the coil. Oversized AC system. Consider going for a well Sized AC unit. Read also: How to Fix High Superheat Low Subcooling.R134a Low Subcooling, High Superheat. This is regarding the refrigeration system for a water cooler. The evaporator is immersed in the water to be cooled. The following information is available at 25 mins after starting the compressor: When water temperature was 7.8 deg. C. Evaporator Inlet: 0.7 deg. C. Suction: 23 deg. C. Discharge: 72.6 deg. C.Low Subcooling • Low on charge • Metering device allowing too much refrigerant flow; piston too large, TXV failing open, piston seating improperly ... Low temperature difference between the boiling point and superheat = low superheat (Below the normal 8-12 deg you should be seeing.. like a 3-7 degree temperature difference.) 1 Like . Reply ...Welcome to Enertech University, online training by Enertech. Measuring subcooling and superheat is a critical diagnostic testing procedure when a unit is not...Compressor superheat: 70°F: ... Remember, the condenser subcooling will be low if an undercharge is causing the bubbling of the sight glass. Otherwise, the bubbling sight glass could mean a restricted liquid line, restricted filter drier, loss of receiver or liquid line subcooling from hot ambient, or static and friction losses in the liquid ...Post Likes. Low subcooling results when there is insufficient refrigerant to fill the lower part of the condenser coil. High suction superheat results when there is insufficient refrigerant to fill the evaporator properly. If you have insufficient refrigerant in both places - it is likely that the system is undercharged.The difference between a low-context and a high-context culture lies in the mode of communication that takes place at the individual dialogue level. In low-context cultures, such a...By Martin King Posted December 9, 2022. In this HVAC Video, I Explain Superheat and Subcooling in the Refrigeration Cycle to Understand the Operation Easier! I go over how to understand the importance of both Superheat and Subcooling. I go over the refrigeration cycle, where superheat is found and what will happen if a Piston or …Many reasons can cause subcooling to occur, including underfeeding, overcharging, restricted meter device, or faulty head pressure control. The effect of subcooling is …A network storage device is one of the best ways to keep your data backed up, but it can be a little pricey to set up and leaving a computer on all the time sucks a lot of power. I...High suction pressure, low discharge pressure and low amp draw. The majority of problems with residential air conditioning systems are due to. electrical problems. As a technician's rule of thumb, fan speed should not be adjusted more than __% above or below manufacturer's specifications. 10.Superheat symptoms, low AC charge symptoms AC blows cold. Then blows warm. The system starts out blowing cold air. But as ice builds up, it blocks the flow of air across the evaporator. Low side pressure drops and the low pressure switch shuts off the AC compressor clutch. At that point, no more cooling is taking place.Conversely, if the valve is stuck open, it can lead to low subcooling. Incorrect Refrigerant Type: Using the wrong type of refrigerant can disrupt the system's performance, causing superheat and subcooling issues. Fixing Low Superheat and Low Subcooling. Check Refrigerant Charge: Start by checking the refrigerant charge using a manifold gauge ...Refrigerant undercharge: When there is not enough refrigerant in the system, it can result in low suction pressure, low head pressure, high superheat, and high sub-cool. Restriction in the refrigerant line: A physical blockage in the refrigerant line can cause reduced suction and head pressure, as well as imbalances in the system.If subcooling is too low, add refrigerant slowly while monitoring changes. For excessive subcooling, carefully remove some refrigerant. ... Superheat and subcool readings guide maintenance decisions. Incorrect readings can lead to wrong diagnoses, causing further system strain. Tools must be calibrated regularly to avoid errors.TXV or cap tube, the superheat heating will vary between 8 °F to 20 °F. On newer systems, which use electronic expansion valves and solid state controllers, it is possible to see the superheat set-ting as low as 5 °F to 10 °F. A low or zero superheat read-ing indicates that the refrigerant did not pick up enough heat inActual Box Temp. Cond Temp should be ±10∘F Actual Cond Temp = Cond Subcooling = (2) Actual Evap Temp = (1) Evap Temp should be TEV 80∘. Question: (7) Symptoms Service Problem 7-4 Cond. Temp: High Low Normal - Walk-in FREEZER Subcooling : High Low Normal - R404A Evap. Temp : High Low Normal - TEV Superheat : High Low Normal (9) Repair ...Preventing Liquid Refrigerant from Entering the Compressor: If the superheat is too low, the refrigerant may exist in both liquid and vapor states. This condition, known as "floodback" or "slugging," can be extremely damaging to the compressor and lead to reduced system efficiency and performance. 2. Ensuring Efficient Cooling: Proper superheat ...Superheat symptoms, low AC charge symptoms AC blows cold. Then blows warm. The system starts out blowing cold air. But as ice builds up, it blocks the flow of air across the evaporator. Low side pressure drops and the low pressure switch shuts off the AC compressor clutch. At that point, no more cooling is taking place.HVAC superheat measures the difference between the vaporized refrigerant's temperature and its saturation temperature. The saturation point, or boiling point, describes when the liquid refrigerant turns to vapor. Saturation occurs when there is a high level of heat and moisture in the air. The evaporator coil turns this moisture into a gas ...For this example the Liquid line Temp is 95 degrees. Subtract the Liquid line Temperature from the Liquid Saturation Temperature and you get a Subcooling of 15. "Typically" on TXV systems the Superheat will range between 8 to 28 degrees with a target of about 10 to 15 degrees. The Subcool range on TXV systems will range from about 8 to 20.When changing the superheat setting on a TXV. Converts high-pressure high temperature liquid refrigerant in to low pressure low temperature mix of vapor and liquid. A metering device is a refrigerant circuit device that. More sub-cooling improves the efficiency and capacity of the system. Which of the following statements about metering devices ...If superheat is low and sub-cooling is low: Orifice could be too big, there is no orifice in the unit of the orifice is stuck and refrigerant is by-passing it. Superheat is telling you what is going on in the evaporator. High Superheat = Starved Evaporator Low Superheat = Flooded Evaporator Sub Cooling is telling you what is going on in the ...CAUSE #2: Defective, plugged, or undersized metering device. Let's say a system has 45 psi suction pressure (converts to 22 ° F) and 68 ° F suction line temperature, the superheat is 46 ° F (68 minus 22). This indicates low refrigerant in the evaporator. However, before adding refrigerant, check the subcooling to be sure the problem isn't ...The less refrigerant flowing through the system, the less the suction line of the system will cool off. You can have a warm suction line (high superheat) due to low charge, a restriction, or high airflow. This indicator is one of many that you need to consider when diagnosing refrigerant problems. Looking at the pinched hose example, we can see ...An undercharge will have low condenser liquid subcooling readings on the high side, where a dirty air filter for the evaporator will not produce low condenser liquid subcooling readings. ... temperature of 26° from the compressor inlet temperature 28° and finds out that there is only 2° of compressor superheat, as shown in this equation ...Jun 19, 2014 · Freezer superheat and subcooling. Hello HVAC tech I am working on a walk in freezer box temp is -10 degrees. this is a R402A refrigerant unit by Larkin it is a Copeland compressor. My suction temp. at the compressor is 33.7 the saturated temp is -32 at 10 psi. the High side is 215 psi saturated temp 89 degrees and the pipe temp is 91 degrees ... rmosden, hvacmatt123 liked this post. A cold suction line (low superheat) with low suction pressure is a symptom of low evaporator air. A liquid restriction would result high superheat (warm suction line). The high head probably due to the other guys overcharging, trying to get the suction pressure up.Low Superheat = Flooded Evaporator Sub Cooling is telling you what is going on in the condenser. High Sub Cooling = Flooded Condenser Low Sub Cooling = Starved Condenser To Determine Delta T (Temperature difference across the coil): 1. While unit is running take the temperature of the air in the supply plenum near the coil (approx 12The superheat value can indicate various system problems including a clogged filter drier, undercharge, overcharge, faulty metering device, restricted airflow, or improper fan motor or blower direction. Suction line superheat is a good place to start diagnosis because a low reading suggests that liquid refrigerant may be reaching the compressor.Are you considering shopping at Lowes for your home improvement needs? Look no further. In this comprehensive guide, we will walk you through everything you need to know about shop...Superheat is measured as the difference between the actual temperature of refrigerant vapor at a certain point and the saturation temperature of the refrigerant. It’s not complicated, but for a beginning tech, it might be.”. Superheat may be so complicated just because of the term “heat,” Tomczyk said. “Because something can be minus ...Starving the evaporator Increasing the system superheat Decreasing the system subcooling Increasing the operating head pressure and compression ratio Question 26 1. In general, air source heat pumps are sized to meet The building cooling capacity The sum of the building heating and cooling capacity Whichever is largest, the cooling capacity or ...Here's the step-by-step guide: Prior to subcooling measurement, the AC unit should be off for at least 30 minutes. This will equalize the refrigerant pressure throughout the unit (lines, coils) since the refrigerant is in a saturated state (mixture of vapor and liquid). Let the air out of the HVAC gauge. Open the vent, listen to that ...4. Low Subcooling Caused Poor Compression (Potential Compressor Problem) 1. Low Refrigerant Charge (Low Subcooling) Or High Refrigerant Charge (High Subcooling) The most common cause for non-normal subcooling is a wrong refrigerant charge. If the system is overcharged (too much freon), we will get high subcooling.Taking care of your pet’s health is essential, but it can be expensive. Fortunately, there are low cost animal clinics available in many areas that can provide quality care without...Low capacity, a starved evaporator, high superheat, and low suction pressure are all symptoms of a(n) _____. ... high subcooling and high compression ratios are all symptoms of a(n) _____. refrigerant overcharge. All reciprocating compressors should immediately go into a vacuum if the suction line is valved off when the compressor is running ...Here is a chart that contains low superheat causes and low subcooling causes: Indoor airflow (CFMs) is too low. Oversized AC unit. Outdoor airflow is too low (or condenser coils heat exchange is impeded). High refrigerant charge (overcharged AC unit). Metering device (TXV, AEV, or piston) is overfeeding.Condenser subcooling: 10° Evaporator superheat: 15° ... The pressure difference between the high and low sides of the refrigeration system is the driving force for the oil to travel from the separator to the crankcase. In the system's layout, the separator is in the high side, and the crankcase in the low side. ...The federal government provides low-income housing in the form of public housing and housing vouchers. Low-income, elderly and disabled renters are eligible. The federal government...On traditional HVACR systems, which utilize mechanical metering devices such as a TXV or cap tube, the superheat heating will vary between 8°F to 20°F. On newer systems, which use electronic expansion valves and solid state controllers, it is possible to see the superheat setting as low as 5°F to 10°F.For subcooling a ballpark range may be somewhere inbetween 10-15 degrees F. For superheat it could be 12-20 degrees F. Check with the manufacturer though. Many units have a charging chart, behind the name plate on the condensing unit, use this first. Charge by superheat for fixed metering devices, and use subcooling for TXV's, if your not ...The unit is 8 years old. Indoor temp= 81, RH=68. Outdoor temp=93. Suction press=65 (should be 38F), Actual suction temp=81F same as room. Superheat=81-38=43 High. Discharge press=350, (should be 143F) Actual temp=130F. Subcool=143-130=13 Normal. Compressor amps rated at 22, pulling only 18.Superheat symptoms, low AC charge symptoms AC blows cold. Then blows warm. The system starts out blowing cold air. But as ice builds up, it blocks the flow of air across the evaporator. Low side pressure drops and the low pressure switch shuts off the AC compressor clutch. At that point, no more cooling is taking place.high: discharge temperature, superheat, subcooling low: head pressure, suction pressure, amperage draw . refrigerant overcharge high side restriction high evaporator airflow low condensing ambient 100. If an equipment nameplate says that the equipment uses dichlorodifluoromethane: The equipment uses R-22 ...If the subcooling is low while the evap coil is frozen and the system is still running, the system is low on refrigerant. An indication of this would be if the subcooling is 3° F or lower. If the system has normal to high subcooling such as 6° F of subcooling or higher, the system is not severely low on refrigerant.non-condensables in the system. Check the "liquid line subcooling" of the system. The "liquid line subcooling" should normally be 7 to 12° F on a 95° F day. If needed, turn fans OFF to approximately duplicate these conditions in colder ambients. If high subcooling is noted along with bubbles in the sight glass, there are non ...What causes Low superheat with high subcool. When both low superheat and high subcooling occur simultaneously, it signals a unique condition that can only be attributed to an overall excess of refrigerant in the system. Overcharging the air conditioning system with refrigerant is the primary cause of experiencing both low superheat and high ...Liquid line temp 101 degrees and the suction was 49 degrees. The low subcooling and low suction pressure indicate low airflow. The somewhat low deltaT seems to contradict that. Could be a significant amount of air bypassing the coil based on your report, which would account for all of the numbers that you posted.Steam at 213 degrees F is superheated by 1 degree F. Superheat is then any temperature of a gas above the boiling point for that liquid. When a refrigerant liquid boils at a low temperature of 40 degrees in a cooling coil and then the refrigerant gas increases in temperature, superheat has been added. If this refrigerant changed from a liquid ...That means understanding and measuring all three types of superheat: evaporator, total, and duct system. 1. Evaporator superheat. To measure evaporator (indoor coil) superheat, first measure the suction line temperature at the evaporator outlet. Next, measure the refrigerant pressure at the suction line of the indoor coil.The high head leads to poor heat rejection and the higher pressures can force more of the available refrigerant into the evaporator and show up as normal or high suction pressure with normal or low superheat. Also make sure the outdoor fan motor is running in the proper direction. Reply.

I had posted in a previous thread about the superheat reading taken on my system being about 11 *F too low (possible overcharge). Today another tech came out and measured everything again. This tech measured the subcooling as well this time. Here are the measurements he took: OAT DB: 68 *F Low side: 68 psi (39 *F) High side: 140 psi (78 *F) High side line temp: 71.7 *F Subcooling: 7 *F .... Erika sandoval verdict

low subcool low superheat

I realize there is a calculation for your target superheat (eg. (IWB)*3-80-(OAT)/2=Target Superheat. However most units that I have come accross DO NOT specify the target subcooling (I speak of TXV/13 SEER units of course). I was wondering if anybody here knew of some calculation to determine this. I realize that 10 degrees will never get you in trouble, but I have read that fixed orifices can ...Calculating superheat can tell us how far liquid Freon is traveling through an evaporator coil. If superheat is too high, there’s less liquid and more gas in the coil. This can cause overheating. If superheat is too low, more liquid and less gas are in the coil. This can cause flooding and damage in the compressor.Liquid Pressure 160 Liquid Line Temp 86. Outdoor dB 82. Indoor wB 68. With those conditions it should have around 18 Superheat, Subcooling varies but, needs to be at least 3-F, with those conditions I'd say, at least 6 to 10-F Subcooling. Okay, with LOW: suction, head pressure, SH, SC, & compressor amp draw.Superheat is calculated as the difference between the saturation temperature of a substance and the actual temperature of the gas. 3 When it comes to HVAC, refrigerants often boil at much lower temperatures than water. For example, if a liquid refrigerant boils at -10 degrees and is then heated up to -5 degrees, it has been …Here is what low superheat and low subcooling means: We get low superheat when the actual measured superheat is 2°F or more degrees lower than the target superheat. You can read how to measure superheat adequately here, and how to read the target …Troubleshooting low superheat. Low superheat values could result from an overcharged system, a dirty condenser coil, or a malfunctioning metering device. Think of it like diagnosing a car that’s not running smoothly – you need to investigate and address the issue! Troubleshooting high subcooling High Subcooling Causes: Low refrigerant charge (undercharged system). Restriction in the liquid line (usually ice). Indoor airflow (CFMs) is too high. Indoor heat load is too high. Metering device (TXV, AEV, or piston) is underfeeding. High refrigerant charge (overcharged system). Restriction in the liquid line (usually ice). Metering device ... The unit is a 3 1/2 Ton heat pump. Original problem was the Evap froze up. Went there and sure enough it was low on charge. TXV equipped. 410A. Data label is calling for a 14 subcool. I put the gauges on and I'm showing a 2. I use a Fieldpiece sman4. I end up putting 15lbs of 410 in and eventually get it to a 12 subcool. Everything is running ...R134a Low Subcooling, High Superheat. This is regarding the refrigeration system for a water cooler. The evaporator is immersed in the water to be cooled. The following information is available at 25 mins after starting the compressor: When water temperature was 7.8 deg. C. Evaporator Inlet: 0.7 deg. C. Suction: 23 deg. C. Discharge: 72.6 deg. C.Measure Superheat: This involves subtracting the actual suction line temperature found by means of a clamp on thermometer from the saturation temperature on the low pressure gauge and compare that to the design saturation point on the pressure temperature chart for that specific ambient.In summary, here are the seven symptoms or telltale signs of a system low on refrigerant: Medium to high discharge temperatures; High evaporator superheat; High compressor superheat; Low condenser subcooling; Low compressor amps; Low evaporator temperatures and pressures; and. Low condensing temperatures and pressures. Publication date: 7/2/2018.High superheat low subcooling on a TXV system means that there is no sufficient amount of refrigerant in the evaporator and there is low amount of the refrigerant in the condenser unit. This condition is mainly caused by low charge in an air conditioning system and can be fixed by sealing leaks and adequately charging the system with a refrigerant..